Chapter 5: Control Interfaces

5.4.2 User Console Software Settings

The Anybus board is set up by sending a Fieldbus Configuration File (*.dspfcf) containing
initialization messages from the Main Unit to the board during power up. This string of data
initializes different characteristics required for the board to communicate over the Interbus S
network. In this string are messages which set the length of I/O data as well as other messages.
Since the board is only initialized during power-up, the Main Unit MUST have the power
cycled OFF/ON after the “dspfcf” file is downloaded.

To download the dspfcf file, select “Field Bus Setup” from the “Main” pull down menu. Select the
appropriate “Bus Type” and click “Browse” to locate the correct dspfcf file. After the file has been
selected, click “download” to send the file data to the Anybus board.


















If no file exists (or if the settings need to be changed), after the Bus Type has been selected,
click on the Setup Tab.


















Select the desired settings from the pull downs. When finished, go back to the General Tab and
click “download” to send the file data to the Anybus board.