Enforce, 2 input signals – FEC DSP1500 Main Unit User Manual

Page 89

Advertising
background image

enFORCE

DSP1500 Main Unit Hardware Manual

PAGE 5 - 49

(Rev. 4.0)

Chapter 5: Control Interfaces

5.8.2 Input Signals

Inputs are assigned in the order as shown in the table below and cannot be changed. Bits
designated as “Unused” have no input assigned to them.

Bit

Signal

Connection

FEC Main

Description

Bank

Bit

RY(n+0)0

Emergency Stop

NC

1

Stop Press operation.

RY(n+0)1

Reset

NO

2

Reset and return to initial status

RY(n+0)2

Return

NO

3

Press jog return operation.

RY(n+0)3 Start

NO

4

Start Press pressing.
In Jog operation, Jog+Start advances the
press

RY(n+0)4

Home

NO

5

Home Search / Return Home

RY(n+0)5 Jog

NO

6

Manual Mode operation
Jog+Start advances the press
Jog+Return returns the press

RY(n+0)6

Seq. / Press Sel. 0

NO

7

Select sequence / press.
Select the sequence No. 1 ~32 at
Sequence Select 0 ~4.
In Jog operation these are the press
selection bits.

RY(n+0)7

Seq. / Press Sel. 1

NO

8

RY(n+0)8

Seq. / Press Sel. 2

NO

9

RY(n+0)9

Seq. / Press Sel. 3

NO

10

RY(n+0)A

Seq. / Press Sel. 4

NO

11

RY(n+0)B Unused

NO

12

RY(n+0)C

INPORT 1

NO

13

Input for Sequence “INPORT 1”.

RY(n+0)D

INPORT 2

NO

14

Input for Sequence “INPORT 2”.

RY(n+0)E

INPORT 3

NO

15

Input for Sequence “INPORT 3”.

RY(n+0)F

INPORT 4

NO

16

Input for Sequence “INPORT 4”.

Bit

Signal

Connection

FEC Main

Description

Bank

Bit

RY(n+1)0

BYPASS PRESS#1

NO

17

Bypass press No. 1.

RY(n+1)1

BYPASS PRESS#2

NO

18

Bypass press No. 2.

RY(n+1)2

BYPASS PRESS#3

NO

19

Bypass press No. 3.

RY(n+1)3

BYPASS PRESS#4

NO

20

Bypass press No. 4.

RY(n+1)4

BYPASS PRESS#5

NO

21

Bypass press No. 5.

RY(n+1)5

BYPASS PRESS#6

NO

22

Bypass press No. 6.

RY(n+1)6

BYPASS PRESS#7

NO

23

Bypass press No. 7.

RY(n+1)7

BYPASS PRESS#8

NO

24

Bypass press No. 8.

RY(n+1)8

BYPASS PRESS#9

NO

25

Bypass press No. 9.

RY(n+1)9

BYPASS PRESS#10

NO

26

Bypass press No. 10.

RY(n+1)A Unused

NO

27

RY(n+1)B Unused

NO

28

RY(n+1)C Unused

NO

29

RY(n+1)D Unused

NO

30

RY(n+1)E Unused

NO

31

RY(n+1)F Unused

NO

32

Bit

Signal

Connection

FEC Main

Description

Bank

Bit

RY(n+2)0

BYPASS PRESS#11

NO

33

Bypass press No. 11.

RY(n+2)1

BYPASS PRESS#12

NO

34

Bypass press No. 12.

RY(n+2)2

BYPASS PRESS#13

NO

35

Bypass press No. 13.

RY(n+2)3

BYPASS PRESS#14

NO

36

Bypass press No. 14.

RY(n+2)4

BYPASS PRESS#15

NO

37

Bypass press No. 15.

RY(n+2)5

BYPASS PRESS#16

NO

38

Bypass press No. 16.

RY(n+2)6

BYPASS PRESS#17

NO

39

Bypass press No. 17.

RY(n+2)7

BYPASS PRESS#18

NO

40

Bypass press No. 18.

RY(n+2)8

BYPASS PRESS#19

NO

41

Bypass press No. 19.

RY(n+2)9

BYPASS PRESS#20

NO

42

Bypass press No. 20.

RY(n+2)A

BYPASS PRESS#21

NO

43

Bypass press No. 21.

RY(n+2)B

BYPASS PRESS#22

NO

44

Bypass press No. 22.

RY(n+2)C

BYPASS PRESS#23

NO

45

Bypass press No. 23.

RY(n+2)D

BYPASS PRESS#24

NO

46

Bypass press No. 24.

RY(n+2)E

BYPASS PRESS#25

NO

47

Bypass press No. 25.

RY(n+2)F

BYPASS PRESS#26

NO

48

Bypass press No. 26.

Advertising