Chapter 5: Control Interfaces

5.7.1 Component Descriptions


Fieldbus Interface Connector

Pin No.

Signal

Description

Housing PE

Protective

Earth

Ground

1

Shield Cable

Shield

2

MBP Line B

Modbus Plus Line B

3

MBP Line A

Modbus Plus Line A

4

NC

-

5

NC

-

6

NC

-

7

NC

-

8

NC

-

(9 pin female D-sub)

9 NC

-



Node ID & Source ID Switches

(S1) Node ID Settings

Function

SW-1

(MSB)

SW-2

SW-3

SW-4 SW-5

SW-6

(LSB)

Address 1

ON

ON

ON

ON

ON

ON

Address 2

ON

ON

ON

ON

ON

OFF

Address 3

ON

ON

ON

ON

OFF

ON

Address 4

ON

ON

ON

ON

OFF

OFF

Address 62

OFF

OFF

OFF

OFF

ON

OFF

Address 63

OFF

OFF

OFF

OFF

OFF

ON

Address 64

OFF

OFF

OFF

OFF

OFF

OFF

(S2) Source ID Settings

Function

SW-1

(MSB)

SW-2

SW-3

SW-4

SW-5 SW-6

(LSB)

Address 1

ON

ON

ON

ON

ON

ON

Address 2

ON

ON

ON

ON

ON

OFF

Address 3

ON

ON

ON

ON

OFF

ON

Address 4

ON

ON

ON

ON

OFF

OFF

Address 62

OFF

OFF

OFF

OFF

ON

OFF

Address 63

OFF

OFF

OFF

OFF

OFF

ON

Address 64

OFF

OFF

OFF

OFF

OFF

OFF

S1 and S2 settings must be made before power is on and cannot be changed during