DSP1500 Main Unit Hardware Manual

(Rev. 4.0)

PAGE 5 - 52

Chapter 5: Control Interfaces

5.9 CC-Link

®

Interface (Version 2)


FEC integrates the CC-Link board (Version 2 setting) manufactured by HMS Fieldbus Systems AB
into the Main Unit’s modular I/O board when CC-link must send both I/O and Message Data. For
further technical information on the CC-Link (Version 2) interface go to the HMS website.
(

www.hms.se

)


NOTE: The FEC CC-Link (V2) module is configured as a “Remote Device Station” when setting up
the parameters in the PLC program.
For detailed information on the Mitsubishi CC-Link Network, see the Mitsubishi User Manual #
13J872 Control & Communication - Link System Master / Local Module.

























Item Description

1 Application

Connector

2 CC-Link

Connector

3

Baud Rate Setting Switch

4

Station Number Setting Switches (2)

5 Status

LEDs

(4)

6 Watchdog

LED

Red - (flashing @ 2Hz) - ASIC and FLASH ROM check fault.
Green (flashing @ 2Hz) - module not initialized.
Green (flashing @ 1Hz) - module initialized and running OK.
Red (flashing @ 1Hz) - RAM check fault.
Red (flashing @ 4Hz) - DPRAM check fault.



Daughter board

3

2

5

1

6

4