Chapter 5: Control Interfaces

The Main Unit is able to operate under different Input/Output control structures through use of a
modular I/O interface board installed in the unit. With the introduction of “Open” communication
networks known as “Fieldbus”, the direct interfacing to these networks became necessary. FEC
integrated many of these Fieldbus directly into our system through use of a modular I/O board
interfacing these networks directly to our I/O.
The available interfaces are shown in the chart below. The fieldbus interface boards are integrated
directly to internal I/O signals which eliminate associated I/O wiring thus reducing overall assembly
labor. In fieldbus systems, the communication is typically of the Master/Slave format in which the
FEC unit is a slave to the master CPU. Some fieldbus types also allow pressing result data
(Messaging) to be sent over the same connection as the I/O signals.

Base Part

Number

Suffix Description

Messaging

MAIN2(E) -1

Discrete I/O (Sink Type)

MAIN2(E)

-2

Discrete I/O (Source Type)

*MAIN2E

-3 DeviceNet-S

®

(for Toolsnet

®

)

X

MAIN2(E)

-4 Reserved

*MAIN2E

-5 Interbus-S

®

(for Toolsnet

®

)

MAIN2(E)

-6

Allen Bradley Remote I/O

*MAIN2E

-7 Profibus

®

(for Toolsnet

®

)

MAIN2(E)

-8 Modbus

Plus

®

MAIN2(E)

-9 DeviceNet-S

®

X

MAIN2(E)

-10 Ethernet

I/P

X

MAIN2(E)

-11 Interbus-S

®

MAIN2(E)

-12 Mitsubishi

CC-Link

®

Ver. 2

X

MAIN2(E)

-13 Profibus

®

MAIN2(E)

-14 Mitsubishi

CC-Link

®

Ver. 1

MAIN2(E)

-15 M-Net

*Toolsnet Interface available for MAIN2E (Ethernet) version only. See Toolsnet Interface Manual for
set up information.

5.1 Interface Board Setup

All I/O Motherboards have a DIP Switch SW1 (located at position 7D) which has to be configured so
the Main Unit can identify the type of interface installed.

Interface Type

SW1

1

SW1

2

SW1

3

SW1

4

Discrete I/O (Sink Type)

ON

OFF

OFF

OFF

Discrete I/O (Source Type)

OFF

ON

OFF

OFF

DeviceNet-S

®

(for Toolsnet

®

)

ON

ON

OFF

OFF

Reserved

OFF

OFF

ON

OFF

Interbus-S

®

(for Toolsnet

®

)

ON

OFF

ON

OFF

Allen Bradley Remote I/O

OFF

ON

ON

OFF

Profibus

®

(for Toolsnet

®

)

ON

ON

ON

OFF

Modbus Plus

®

OFF

OFF

OFF

ON

DeviceNet-S

®

ON

OFF

OFF

ON

Ethernet I/P

OFF

ON

OFF

ON

Interbus-S

®

ON

ON

OFF

ON

Mitsubishi CC-Link

®

Version 2

OFF

OFF

ON

ON

Profibus

®

ON

OFF

ON

ON

Mitsubishi CC-Link

®

Version 1

OFF

ON

ON

ON

M-Net

ON

ON

ON

ON


Throughout this chapter, SW1 settings will be represented as follows: