4-3-6.

Input Port Query (20BH)

Function: Query input ports.

Data name

Data range (value)

Data size

[bytes]

Cumulative bytes

[bytes]

Endian Sign

extension

Unit

Description Remarks

Big Little Yes No

Command

Header '!'

1

1

Station 'XX(h)'

2

3

Message ID

'20B(h)'

3

6

Query start port
number

'XXXX(h)' 4

10 

Be sure to specify “Category head port
number + Multiple of 8.”

Number of query
ports

'XXXX(h)' 4

14 

The number of ports will be limited based on
the send/receive buffers.

SC 'XX(h)'

2

16

CR 0Dh

1

17

LF 0Ah

1

18

Normal response

Header '#'

1

1

Station 'XX(h)'

2

3

Message ID

'20B(h)'

3

6

Response start port
number

'XXXX(h)' 4

10 

Number of response
ports

'XXXX(h)' 4

14 

The number of ports will be limited based on
the send/receive buffers.

Input port data (*1)

'XX(h)'

2

16

8 bits from the head input port

Remaining input port
data

Data indicated by *1

for the number of

remaining data

MAX

16382

MAX

16398

Remaining input port data = 2 bytes x (Max
8192 – 1) = 16382 bytes

SC 'XX(h)'

2

MAX

16400

CR 0Dh

1

MAX

16401

LF 0Ah

1

MAX

16402

Error

respon

se

Error response
format

Refer to the error

response format.

10 10