IAI America TTA User Manual

Page 46

Advertising
background image

-46/85-


4-3-28. Positon Data Clear (Old: Point Data Clear) (246H)

Function: Clear position data for the number of clear positions from the clear start position number. (Position data comments cannot be cleared.)

Data name

Data range (value)

Data size

[bytes]

Cumulative

bytes [bytes]

Endian Sign

extension

Unit

Description Remarks

Big Little Yes No

Command

Header '!'

1

1

Station 'XX(h)'

2

3

Message ID

'246(h)'

3

6

Clear start position
data number

'XXX(h)' 3 9

Number of clear
position data

'XXX(h)' 3 12

SC 'XX(h)'

2

14

CR 0Dh

1

15

LF 0Ah

1

16

Normal

response

Header '#'

1

1

Station 'XX(h)'

2

3

Message ID

'246(h)'

3

6

SC 'XX(h)'

2

8

CR 0Dh

1

9

LF 0Ah

1

10

Error

respon

se

Error response
format

Refer to the error

response format.

10 10

(Note 1) Add H (or h) at the end of each data expressed in hexadecimal notation. If there is no H or h at the end, the data is considered a decimal.
(Note 2) Data enclosed in single quotation marks indicates an ASCII code. Data is a hexadecimal ASCII code if (h) is added before the closing quotation mark, or a decimal ASCII code if (d) is

added before the closing quotation mark.