IAI America TTA User Manual

Page 64

Advertising
background image

-64/85-


4-3-46. Change Position Data Continuous Write 3 (Old: Change Point Data Continuous Write 3) (291H)

Function: Change the specified position data for the number of change position from the change start position number.

Data name

Data range (value)

Data size

[bytes]

Cumulative

bytes [bytes]

Endian

Sign extension

Unit Description

Remarks

Big

Little

Yes

No

Command

Header '!'

1

1

Station 'XX(h)'

2

3

Message ID

'291(h)'

3

6

Reserved for system use

’00(h)’

2

8

Change start position
data number

'XXXX(h)' 4 9

Number of change
position data

'XXXX(h)' 4 12

The number of data will be limited based on the
send/receive buffers.

Posi

tion

data

(

*1)

Axis pattern

'XX(h)'

2

14

Acceleration 'XXXX(h)'

4

18

 0.01

G

Deceleration 'XXXX(h)'

4

22

0.01 G

Speed 'XXXX(h)'

4

26

mm/sec

Position data (*2)

'XXXXXXXX(h)'

8

34

0.001 mm

Position data
repetition for
remaining effective
axes

Data indicated by *2

for the number of

remaining effective

axes

MAX

56

MAX

90

0.001

mm

Data indicated by *2 x Number of remaining effective
axes = 8 bytes x (Max 8 – 1) axes = Max 56 bytes

Extended data

‘XX(h)’

2

MAX 96

Bits 0 to 3 (spare)
Bits 4 to 5 (SCARA 1 arm system data): 0 = No
specification / 1 = Right arm system / 2 = Left arm
system
Bits 6 to 7 (SCARA 2 arm system data): 0 = No
specification / 1 = Right arm system / 2 = Left arm
system

Position data repetition
for remaining data

Data indicated by *1

for the number of

remaining data

MAX

1679916

MAX

1680012

Refer to the data indicated by *1.

Data indicated by *1 x Number of remaining data =
Max 84 bytes x (Max 20000 data – 1) = Max
1679916 bytes

SC 'XX(h)'

2

MAX

1680014

CR 0Dh

1

MAX

1680015

LF 0Ah

1

MAX

1680016

Normal

re

spon

se

Header '#'

1

1

Station 'XX(h)'

2

3

Message ID

'291(h)'

3

6

Reserved for system use

’00(h)’

2

8

Number of changed
position data

'XXXX(h)' 4 12

The number of data will be limited based on the
send/receive buffers.

SC 'XX(h)'

2

14

CR 0Dh

1

15

LF 0Ah

1

16

Error

respon

se

Error response format

Refer to the error

response format.

10 10

(Note 1)

Add H (or h) at the end of each data expressed in hexadecimal notation. If there is no H or h at the end, the data is considered a decimal.

(Note 2)

Data enclosed in single quotation marks indicates an ASCII code. Data is a hexadecimal ASCII code if (h) is added before the closing quotation mark, or a decimal ASCII code if (d) is added before the closing
quotation mark.

Advertising