4-3-31. Integer Variable Change (24CH)

Function: Change integer variables for the number of change data from the change start variable number.

Data name

Data range (value)

Data size

[bytes]

Cumulative

bytes [bytes]

Endian Sign

extension

Unit

Description Remarks

Big Little Yes No

Command

Header '!'

1

1

Station 'XX(h)'

2

3

Message ID

'24C(h)'

3

6

Program number

'XX(h)'

2

8

‘00’ in the case of a global variable

Change start variable
number

'XXX(h)' 3 11

Number of change
variable data

'XX(h)' 2 13

The number of data will be limited based on the
send/receive buffers.

Integer variable data
(*1)

'XXXXXXXX(h)' 8

21 

(Hexadecimal ASCII code)

Remaining integer
variable data

Data indicated by *1

for the number of

remaining data

MAX
2032

MAX
2053

Data indicated by *1 x Number of remaining data
= 8 bytes x Max (FFh – 1) = Max 2032 bytes

SC 'XX(h)'

2

MAX
2055

CR 0Dh

1

MAX
2056

LF 0Ah

1

MAX
2057

Normal response

Header '#'

1

1

Station 'XX(h)'

2

3

Message ID

'24C(h)'

3

6

Program number

'XX(h)'

2

8

‘00’ in the case of a global variable

Change start variable
number

'XXX(h)' 3 11

Number of changed
data

'XX(h)' 2 13

The number of data will be limited based on the
send/receive buffers.

SC 'XX(h)'

2

15

CR 0Dh

1

16

LF 0Ah

1

17

Error

respon

se

Error response
format

Refer to the error

response format.

10 10

(Note 1) Add H (or h) at the end of each data expressed in hexadecimal notation. If there is no H or h at the end, the data is considered a decimal.