4-3-29. Output Port Status Change (24AH)

Function: Change the status of the output port specified by the output port number.

Data name

Data range (value)

Data size

[bytes]

Cumulative

bytes [bytes]

Endian Sign

extension

Unit

Description Remarks

Big Little Yes No

Command

Header '!'

1

1

Station 'XX(h)'

2

3

Message ID

'24A(h)'

3

6

Output port number

'XXXX(h)'

4

10

Change type

'X(h)'

1

11

Bit 1 to 3 (Reserved for system use) are fixed to 0.
Bit 0 (Output port ON/OFF): 0 = OFF / 1 = ON

SC 'XX(h)'

2

13

CR 0Dh

1

14

LF 0Ah

1

15

Normal

response

Header '#'

1

1

Station 'XX(h)'

2

3

Message ID

'24A(h)'

3

6

SC 'XX(h)'

2

8

CR 0Dh

1

9

LF 0Ah

1

10

Error

respon

se

Error response
format

Refer to the error

response format.

10 10

(Note 1) Add H (or h) at the end of each data expressed in hexadecimal notation. If there is no H or h at the end, the data is considered a decimal.