4-3-30. Flag Status Change (24BH)

Function: Change the status of the flag specified by the flag number.

Data name

Data range (value)

Data size

[bytes]

Cumulative

bytes [bytes]

Endian Sign

extension

Unit

Description Remarks

Big Little Yes No

Command

Header '!'

1

1

Station 'XX(h)'

2

3

Message ID

'24B(h)'

3

6

Program number

'XX(h)'

2

8

‘00’ in the case of a global flag

Flag number

'XXXX(h)'

4

12

Change

type

'X(h)'

1

13

SC 'XX(h)'

2

15

Bit 1 to 3 (Reserved for system use) are fixed to 0.
Bit 0 (Output port ON/OFF): 0 = OFF / 1 = ON

CR 0Dh

1

16

LF 0Ah

1

17

Normal

response

Header '#'

1

1

Station 'XX(h)'

2

3

Message ID

'24B(h)'

3

6

SC 'XX(h)'

2

8

CR 0Dh

1

9

LF 0Ah

1

10

Error

respon

se

Error response
format

Refer to the error

response format.

10 10

(Note 1) Add H (or h) at the end of each data expressed in hexadecimal notation. If there is no H or h at the end, the data is considered a decimal.
(Note 2) Data enclosed in single quotation marks indicates an ASCII code. Data is a hexadecimal ASCII code if (h) is added before the closing quotation mark, or a decimal ASCII code if (d) is