IAI America TTA User Manual

Page 30

Advertising
background image

-30/85-


4-3-14. System Status Query (215H)

Function: Query the system status.

Data name

Data range (value)

Data size

[bytes]

Cumulative

bytes [bytes]

Endian Sign

extension

Unit

Description Remarks

Big Little Yes No

Command

Header '!'

1

1

Station 'XX(h)'

2

3

Message ID

'215(h)'

3

6

SC 'XX(h)'

2

8

CR 0Dh

1

9

LF 0Ah

1

10

Normal response

Header '#'

1

1

Station 'XX(h)'

2

3

Message ID

'215(h)'

3

6

System mode

'X(h)'

1

7

0 = Indeterminable / 1 = AUTO mode / 2 =
MANUAL mode / 3 = Slave update mode / 4
= Core update mode

*1

Critical level system
error number

'XXX(h)' 3 10

*2

Latest system error
number

'XXX(h)' 3 13

*3

System status byte 1

'XX(h)'

2

15

Bit 7 (Reserved for system use)
Bit 6 (Battery voltage error status): 0 = No
error /1 = Error
Bit 5 (Battery voltage low warning status): 0
= Not low / 1 = Low
Bit 4 (Power error status): 0 = Normal / 1 =
Error
Bit 3 (Emergency stop switch status): 0 = No
emergency stop / 1 = Emergency stop
Bit 2 (Safety gate status): 0 = CLOSE / 1 =
OPEN
* When
X-SEL-P/Q/PCT/QCT/PX/QX/R/S/RX/SX/R
XD/SXD, SSEL, ASEL/PSEL controller or
TTA is used, this bit indicates the status of
an enable switch (deadman switch/enable
switch).
Bit 1 (TP enable switch status): 0 = ON / 1 =
OFF
* When
X-SEL-P/Q/PCT/QCT/PX/QX/R/S/RX/SX/R
XD/SXD, SSEL, ASEL/PSEL controller or
TTA is used, this bit is invalid (fixed to 0).
Bit 0 (Operation mode switch status): 0 =
AUTO / 1 = MANUAL

*4