IAI America TTA User Manual

Page 38

Advertising
background image

-38/85-


4-3-20. Home Return (233H)

Function: Perform home return. * With the SCARA (axis) type, this message can be used only by IAI as a “Z-axis ABS reset position movement” command.

Data name

Data range (value)

Data size

[bytes]

Cumulative

bytes [bytes]

Endian Sign

extension

Unit

Description Remarks

Big Little Yes No

Command

Header '!'

1

1

Station 'XX(h)'

2

3

Message ID

'233(h)'

3

6

Axis pattern

'XX(h)'

2

8

For the X-SEL-PX/QX/RX/SX series, specify
only direct-acting axes.

End search speed at
home return

'XXX(h)' 3 11

mm/sec

The parameter setting becomes effective if zero.

Creep speed at home
return

'XXX(h)' 3 14

mm/sec

The parameter setting becomes effective if zero.

SC 'XX(h)'

2

16

CR 0Dh

1

17

LF 0Ah

1

18

Normal

response

Header '#'

1

1

Station 'XX(h)'

2

3

Message ID

'233(h)'

3

6

SC 'XX(h)'

2

8

CR 0Dh

1

9

LF 0Ah

1

10

Error

respon

se

Error response
format

Refer to the error

response format.

10 10

(Note 1) Add H (or h) at the end of each data expressed in hexadecimal notation. If there is no H or h at the end, the data is considered a decimal.
(Note 2) Data enclosed in single quotation marks indicates an ASCII code. Data is a hexadecimal ASCII code if (h) is added before the closing quotation mark, or a decimal ASCII code if (d) is

added before the closing quotation mark.