IAI America TTA User Manual

Page 53

Advertising
background image

-53/85-


4-3-35. Program Run (253H), Program End (254H),

Program Pause (255H), Program One-Step Run (256H), Program Resume (257H)

Function: Run, end, run one step of, pause between steps of, or resume the specified program.

Data name

Data range (value)

Data size

[bytes]

Cumulative

bytes [bytes]

Endian Sign

extension

Unit

Description Remarks

Big Little Yes No

Command

Header '!'

1

1

Station 'XX(h)'

2

3

Message ID

'XXX(h)'

3

6

Program number

'XX(h)'

2

8

When an end, pause or resume command is
issued with ‘00’ specified, it will apply to all
programs currently running.

SC 'XX(h)'

2

10

CR 0Dh

1

11

LF 0Ah

1

12

Normal

response

Header '#'

1

1

Station 'XX(h)'

2

3

Message ID

'XXX(h)'

3

6

SC 'XX(h)'

2

8

CR 0Dh

1

9

LF 0Ah

1

10

Error

respon

se

Error response
format

Refer to the error

response format.

10 10

(Note 1) Add H (or h) at the end of each data expressed in hexadecimal notation. If there is no H or h at the end, the data is considered a decimal.
(Note 2) Data enclosed in single quotation marks indicates an ASCII code. Data is a hexadecimal ASCII code if (h) is added before the closing quotation mark, or a decimal ASCII code if (d) is