IAI America TTA User Manual
Page 53
![background image](/manuals/350332/53/background.png)
-53/85-
4-3-35. Program Run (253H), Program End (254H),
Program Pause (255H), Program One-Step Run (256H), Program Resume (257H)
Function: Run, end, run one step of, pause between steps of, or resume the specified program.
Data name
Data range (value)
Data size
[bytes]
Cumulative
bytes [bytes]
Endian Sign
extension
Unit
Description Remarks
Big Little Yes No
Command
Header '!'
1
1
Station 'XX(h)'
2
3
Message ID
'XXX(h)'
3
6
Program number
'XX(h)'
2
8
When an end, pause or resume command is
issued with ‘00’ specified, it will apply to all
programs currently running.
SC 'XX(h)'
2
10
CR 0Dh
1
11
LF 0Ah
1
12
Normal
response
Header '#'
1
1
Station 'XX(h)'
2
3
Message ID
'XXX(h)'
3
6
SC 'XX(h)'
2
8
CR 0Dh
1
9
LF 0Ah
1
10
Error
respon
se
Error response
format
Refer to the error
response format.
10 10
(Note 1) Add H (or h) at the end of each data expressed in hexadecimal notation. If there is no H or h at the end, the data is considered a decimal.
(Note 2) Data enclosed in single quotation marks indicates an ASCII code. Data is a hexadecimal ASCII code if (h) is added before the closing quotation mark, or a decimal ASCII code if (d) is
added before the closing quotation mark.