Placing global settings in the generation block – Teledyne LeCroy STX M6-1 SAS_SATA Protocol Analyzer User Manual User Manual
Page 385

Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
383
Overview of Generation and Global Settings Files
LeCroy Corporation
Placing Global Settings in the Generation Block
Some global settings such as AutoAlign = On/Off can be set and reset in the generation
block. For example, you might want to set SASAutoAlign = ON prior to traffic generation,
and then change to OFF halfway through the generation session.
When placed within the generation block and then viewed in the trace window, global
settings appear as colored bars interspersed amidst the traffic.
While most global settings can be set in the generation block, three will be ignored if
placed within the generation block:
set Link Speed =
set GenerationMode =
set SSC =
These commands should be configured either in the Setting.inc file or at the beginning of
the traffic generation file as a global statement.