Vanguard CT-8000 User Manual

Page 103

Advertising
background image

REV 2 CT-8000 USER’S MANUAL

98

4.2

Performing a Transducer Self-Test

You can check the transducer electronics by connecting the transducer to the CT-8000 and
running a transducer self-test using the instructions below:

a. Start from the “START-UP” menu:

Press the

[4]

key (DIAGNOSTICS).

b. The following screen will be displayed:

Press the

[3]

key (TEST TRANSDUCER).

c. The following screen will be displayed:

Move the transducer slider to a known distance and observe the display.

d. The screen will be updated with the new transducer position information:

If the transducer was moved 5 inches, the screen should display 5.00 IN. You can
continue to move the transducer slider and observe the screen values to make sure they
are correct. Press the

[STOP]

key to end the test and return to the “START-UP” menu.

TRANSDUCER TEST:
1= 5.00 IN / 360.0

x

2= 0.00 IN / 000.0

x

2= 0.00 IN / 000.0

x

TRANSDUCER TEST:
1= 0.00 IN / 000.0

x

2= 0.00 IN / 000.0

x

2= 0.00 IN / 000.0

x

1. SLOW CLOSE TEST

2. CHECK HOOKUP

3. TEST TRANSDUCER

4. NEXT PAGE

1. RUN TEST 03/10/10

2. GET RSLT 09:04:05

3. SETUP

4. DIAGNOSTICS

Advertising