Chapter 6 display configuration, 1 setting a display group, Chapter 6 dsplay confguraton – Yokogawa Button Operated MV2000 User Manual

Page 155: 1 setting a display group -1, 1 settng a dsplay group

Advertising
background image

6-1

IM MV1000-01E

D

splay Conf

gurat

on

1

2

3

4

5

6

7

8

9

10

11

12

13

App

Index

Chapter 6

Dsplay Confguraton

6.1 Settng a Dsplay Group

This section explains how to assign channels to a display group and how to name the
group. It also explains how to set lines at specified positions in the waveform display
range on the trend display.

Dsplay

Press

MENU and then select Menu tab > Group set, Trp lne.

Settngs

• Group number

Select the target group number (from 1 to 10 on the MV1000 and 1 to 36 on the

MV2000).

• Group set

• On/Off

Select On to use the group.

• Group name

Set the group name (up to 16 characters,

A a # 1

).

• CH set

Select measurement channels, computation channels (/M1 and /PM1 options), and

external input channels (/MC1 option) that you want to assign to the group. You can
set up to 6 channels on the MV1000 and up to 10 channels on the MV2000.

• Enter channel numbers using two or three digits.
• Separate each channel number with a period.
• To specify a range of consecutive channels numbers, use a hyphen.
Example: To assign channel 1 and channels 5 through 8, enter “001.005-008.”

Note

• The MV displays the channels in the specified order on the trend, digital, and bar graph

displays.

• You can assign a channel to multiple groups.
• You cannot assign a channel twice to the same group.