2-14
IM MV1000-01E
24 VDC Transmtter Power Supply Termnal (/TPS2, /TPS4)
Connect the MV to the transmitter as shown below:
–
+
+
–
Transmitter
Current
MV
Transmitter power
supply output
terminal
Input terminal
Shunt resistor: 250 Ω
Note
To reduce noise, use a shielded cable for wiring. Connect the shield to the functional ground
terminal or to the ground terminal of the MV.
2.3 Optonal Termnal Wrng