7-9

Output Format

7

7.9

Report Output Format

Hourly report

The hourly report is output in the following format with the command, TS4+device
trigger(GET)+RF0.

Data

length

Year Month Day

Hour Minute 0

A1 B1

C1

D1

An Bn

Cn

Dn

Number of output bytes

Time when the report is created

First channel

Last channel

A1 to An: Report channel number ( 00H to 3BH)
B1 to Bn: Unit number (Fixed to 80H during computation)
C1 to Cn: Channel number*
D1 to Dn: Report computation type
*: Computation channels are

00H to 1DH for stand-alone type
00H to 3BH for extended type

0

Extension

number

Power failure data 0: no failure 1:failure occurred

0 or 1

A1

An

A1

An

A1

An

E1

F1

G1

DATA H1

En

Fn

Gn

DATA Hn

E1

F1

I1

DATA J1

DATA Jn

E1

F1

K1

DATA L1

DATA Ln

En

Fn In

En

Fn

Kn

Report computation data for each report channel

A1 ot An: Report channel number : 00H to 3BH
E1 to En:
Type of the report computation result to output
F1 to Fn: Report computation data status
G1 to Gn, l1 to ln, K1 to Kn:
Mantissa of the report computation data
Data H1 to data Hn:
Mantissa of the report computation data
Data J1 to data Jn:
Mantissa of the report computation data
Data L1 to data Ln:
Mantissa of the report computation data

Starting date and time of the sum for TOTAL

Instantaneous value, average value
or summed value

Minimum value or Total of
the summed values

Maximum value

Year Month Day

Hour Minute

Note

• RF0 outputs data on the specified report channles.

Data length

The number of output bytes can be determined from the following expression.

Number of output bytes = 16 + 4 x N + 8 x N x 3 + (8 + 8 + N) x extension number

N: Number of output channels

Report computation type

Output the type of computation set for each report channel.
00H: OFF
01H: INST (Instantaneous value)
02H: AVE (Average)
03H: SUM (Sum)

The type of report computation result to output

The report computation results vary depending on the report computation types. The following
types of report computation results are output.

Output value

Type of report computation result to output

Report computation type

00H

Invalid data

OFF

01H

INST (instantaneous value)

INST

02H

AVE (average value)

AVE

03H

SUM (summed value)

SUM

04H

MIN (minimum value)

AVE

05H

MAX (maximum value)

AVE

06H

TOTAL (total of the summed values)

SUM