Output the system configuration data – Yokogawa DA100 User Manual

Page 93

Advertising
background image

IM DA100-11E

8-12

8.3 RS-422-A/RS-485 Sample Programs

Output the System Configuration Data

Read out the configuration data from DA100, display on CRT of the personal computer, and save to
floppy disk.

10

20

OPEN “COM1:E81N” AS #1

30

OPEN “TS5.DAT” FOR OUTPUT AS #2

40

50

PRINT #1,CHR$(&H1B)+”O 01"

60

LINE INPUT #1,D$ :PRINT D$

70

PRINT #1,”TS5"

80

LINE INPUT #1,D$ :PRINT D$

90

PRINT #1,CHR$(&H1B)+”T”

100

LINE INPUT #1,D$ :PRINT D$

110

PRINT #1,”CF0"

120

LINE INPUT #1,D$

130

PRINT D$

140

PRINT #2,D$

150

IF LEFT$(D$,2)<>”E:” THEN GOTO 120

160

170

PRINT #1,CHR$(&H1B)+”C 01"

180

LINE INPUT #1,D$ :PRINT D$

190

CLOSE

200

END