Yokogawa DA100 User Manual
Page 90
Advertising

IM DA100-11E
8-9
Sample Program
8
Output the Measurement Data (ASCII Code, four-wire)
Read out the measurement data by ASCII code from DA100, display on CRT of the personal computer,
and save to floppy disk.
10
‘
20
OPEN “COM1:E81N” AS #1
30
OPEN “TS0ASC.DAT” FOR OUTPUT AS #2
40
‘
50
PRINT #1,CHR$(&H1B)+”O 01"
60
LINE INPUT #1,D$ :PRINT D$
70
PRINT #1,”TS0"
80
LINE INPUT #1,D$ :PRINT D$
90
PRINT #1,CHR$(&H1B)+”T”
100
LINE INPUT #1,D$ :PRINT D$
110
PRINT #1,”FM0,001,010"
120
LINE INPUT #1,D$
130
PRINT D$
140
PRINT #2,D$
150
IF MID$(D$,2,1)<>”E” THEN GOTO 120
160
‘
170
PRINT #1,CHR$(&H1B)+”C 01"
180
LINE INPUT #1,D$ :PRINT D$
190
CLOSE
200
END
8.3 RS-422-A/RS-485 Sample Programs