Cdaqda100reader::getinfoch, Cdaqda100reader::getinstch – Yokogawa PC-Based MX100 User Manual

Page 1037

Advertising
background image

19-43

IM MX190-01E

19

DARWIN for Extended API - Visual C++

CDAQDA100Reader::getInfoCh

Syntax

virtual int getInfoCh(int sChType, int sChNo, int eChType, int
eChNo);

Parameters

sChType

Specify the start channel type.

sChNo

Specify the start channel number.

eChType

Specify the end channel type.

eChNo

Specify the end channel number.

Description

Gets the channel information data of the specified channel range.
The specified data is stored in the data member.

This function executes the EL command of the communication interface.

Return value

Returns an error number.

Reference

getChInfo getClassDataBuffer send CDAQDARWINChInfo::toChName
CDAQDARWINDataBuffer::setChInfo

CDAQDA100Reader::getInstCh

Syntax

int getInstCh(int sChType, int sChNo, int eChType, int eChNo);

Parameters

sChType

Specify the start channel type.

sChNo

Specify the start channel number.

eChType

Specify the end channel type.

eChNo

Specify the end channel number.

Description

Gets the measured data of the measured channel range.
The specified data is stored in the data member.

This function executes the EB and EF commands of the communication interface.

Return value

Returns an error number.
Error:

Not data

Received data insufficient.

Reference

getChDataByBinary getClassDataBuffer receive runCommand send
CDAQDARWINChInfo::toChName CDAQDARWINDataBuffer::setDataInfo
CDAQDARWINDataBuffer::setDateTime CDAQDARWINDateTime::setByte

19.6 Details of the DARWIN Class

Advertising