Resetbalancemx – Yokogawa PC-Based MX100 User Manual

Page 295

Advertising
background image

5-37

IM MX190-01E

Functions for the MX100 (Visual C/Visual Basic)

5

resetBalanceMX

Syntax

int resetBalanceMX(DAQMX daqmx, MXBalanceData *
pMXBalanceData, MXBalanceResult * pMXBalanceResult);

Declaration

Public Declare Function resetBalanceMX Lib "DAQMX"(ByVal daqmx
As Long, ByRef pMXBalanceData As MXBalanceData, ByRef
pMXBalanceResult As MXBalanceResult) As Long

Parameters

daqmx

Specify the device descriptor.

pMXBalanceData

Specify initial balance data.

pMXBalanceResult

Specify the destination where the initial balance result is to
be returned.

Description

Initializes the initial balance value.
• Executed on channels whose initial balance data items are set to Valid.

• The initial balance value is returned to the initial balance data. Also, the channel-

by-channel initial balance results are returned to the specified return destination.

When this occurs, only the data from channels whose initial balance data items
are set to Valid is overwritten.

• The response to this function may take five seconds or longer.

Return value

Returns an error number.

Error:
Not descriptor

No device descriptor.

Reference

CDAQMX::restBalance
CDAQMXBalanceResult::getMXBalanceData
CDAQMXBalanceResult::getMXBalanceResult

5.1 Details of Functions - MX100 (Visual C/Visual Basic) -

Advertising