12-4

IM MX190-01E

Control Functions

Function

FIFO

Class and Member Function

Set date/time Current time

Stop

CDAQMX100:: setDateTime

Set backup valid/invalid

Continue

CDAQMX100:: switchBackup

Format of the CF card

Stop

CDAQMX100:: formatCF

Unit

Reconfigure

Stop

CDAQMX100:: reconstruct

Initialize

Stop

CDAQMX100:: initSetValue

Reset alarm

Stop

CDAQMX100:: ackAlarm

(alarm ACK)

7-segment LED display

Continue

CDAQMX100:: displaySegment

Initialize stored data

Specify channel

Continue

CDAQMX100:: initDataCh

Specify FIFO

Continue

CDAQMX100:: initDataFIFO

At the end of communications, the control function updates the status.
See the data manipulation functions for more about the data transmission and setup

functions.

Setup Functions

Function

FIFO Class and Member Function

Setup data Collectively

All setup data

Stop CDAQMX100:: sendConfig

(send collectively) Basic setup data

Stop CDAQMX100:: sendConfig

Individually

System config data

Stop CDAQMX100:: sendConfig

Channel setup data Stop CDAQMX100:: sendConfig

Initial balance data

Stop CDAQMX100:: sendConfig

Output channel data Stop CDAQMX100:: sendConfig

Initial balnc Execute

Stop CDAQMX100:: initBalance

data

Reset

Stop CDAQMX100:: clearBalance

The setup data setup functions send the data being stored.
When setting arbitrary initial balance data, see the initial balance data sending

function under data manipulation functions.