Retrieval of the measured data – Yokogawa PC-Based MX100 User Manual

Page 1078

Advertising
background image

22-11

IM MX190-01E

22

DARWIN for Extended API - Visual Basic.NET -

Retrieval of the Measured Data

Program Example

Module Module1
Public Sub Meas()
Dim comm As Integer
Dim rc As Integer
Dim value As Integer
'connect
comm = openDA100Reader("192.168.1.11", rc)
'get
rc = measInstChDA100Reader(comm, 0, 1)
value = dataValueDA100Reader(comm, 0, 1)
'disconnect
rc = closeDA100Reader(comm)
End Sub
End Module

Description

Overview
Retrieves instantaneous values of the measured data from channel 1 of DARWIN

subunit number 0 and stores them in the field. Reads the measured values and
concludes the process.

Communication Connection
comm = openDA100Reader("192.168.1.11", rc)
The IP address of the DARWIN is specified. This statement specifies the

communication constant for the port number for loading the instantaneous value
data.

Retrieval of the Measured Data of Channel 1
rc = measInstChDA100Reader(comm, 0, 1)
Retrieves instantaneous values of the measured data from channel 1 of DARWIN
subunit number 0 and stores them in the field.

Retrieval of Measured Values
value = dataValueDA100Reader(comm, 0, 1)
Reads the measured value of channel 1 of subunit number 0 from the field where

the measured data is stored.

Comm. cut
rc = closeDA100Reader(comm)
Drops the connection.

22.4 Program for Loading Instantaneous Value Data -DARWIN/Visual Basic.NET-

Advertising