17-96

IM MX190-01E

alarmHisterisysMX100

Syntax

int alarmHisterisysMX100(DAQMX100 daqmx100, int chNo, int
levelNo);

Declaration

Visual Basic
Public Declare Function alarmHisterisysMX100 Lib
"DAQMX100"(ByVal daqmx100 As Long, ByVal chNo As Long, ByVal
levelNo As Long) As Long
Visual Basic.NET
Public Declare Ansi Function alarmHisterisysMX100 Lib
"DAQMX100"(ByVal daqmx100 As Integer, ByVal chNo As Integer,
ByVal levelNo As Integer) As Integer
C#
[DllImport("DAQMX100.dll" CharSet=CharSet.Auto,
EntryPoint="alarmHisterisysMX100")]
public static extern int alarmHisterisysMX100(int daqmx100,
int chNo, int levelNo);

Parameters

daqmx100

Specify the device descriptor.

chNo

Specify the channel number.

levelNo

Specify the alarm level.

Description

Gets the specified channel number and alarm level hysteresis from the stored

current channel setting data.
• The return value is an integer excluding the decimal point position.

• Returns 0 if it does not exist.

Return value

Returns the hysteresis.

Reference

CDAQMX100::getClassMXItemConfig
CDAQMXItemConfig::getHisterisys

17.2 Details of Function - MX00 (Visual C/Visual Basic/Visual Basic.NET/C#) - Retrieval Functions