10 setrtddarwin – Yokogawa PC-Based MX100 User Manual

Page 533

Advertising
background image

10-35

IM MX190-01E

Functions for the DARWIN - Visual C/Visual Basic -

10

setRTDDARWIN

Syntax

int setRTDDARWIN(DAQDARWIN daqdarwin, int iRangeRTD, int
chType, int startChNo, int endChNo, int spanMin, int spanMax,
int scaleMin, int scaleMax, int scalePoint);

Declaration

Public Declare Function setRTDDARWIN Lib "DAQDARWIN"(ByVal
daqdarwin As Long, ByVal iRangeRTD As Long, ByVal chType As
Long, ByVal startChNo As Long, ByVal endChNo As Long, ByVal
spanMin As Long, ByVal spanMax As Long, ByVal scaleMin As
Long, ByVal scaleMax As Long, ByVal scalePoint As Long) As
Long

Parameters

daqdarwin

Specify the device descriptor.

iRangeRTD

Specify the range type of the RTD input.

chType

Specify the channel type.

startChNo

Specify the start channel number.

endChNo

Specify the end channel number.

spanMin

Specify the left value of the span.

spanMax

Specify the right value of the span.

scaleMin

Specify the left value of the scale.

scaleMax

Specify the right value of the scale.

scalePoint

Specify the decimal point position for scaling.

Description

Sets the specified RTD range to the channels in the specified channel range

(specified by channel type, start channel number, and end channel number).
• With the span and scale specification, if the left and right values are the same,

they are considered omitted.

• This function executes the SR command of the DARWIN communication

function.

Return value

Returns an error number.

Error:
Not descriptor

No device descriptor.

Reference

CDAQDARWIN::setRTD

10.1 Details of Functions - DARWIN (Visual C/Visual Basic) -