7cdaqdarwin::setma – Yokogawa PC-Based MX100 User Manual

Page 427

Advertising
background image

7-29

IM MX190-01E

DARWIN - Visual C++ -

7

CDAQDARWIN::setMA

Syntax

int setMA(int iRangeMA, int chType, int startChNo, int endChNo
= 0, int spanMin = 0, int spanMax = 0, int scaleMin = 0, int
scaleMax = 0, int scalePoint = 0);

Parameters

iRangeMA

Specify the DC current range.

chType

Specify the channel type of the measurement channel.

startChNo

Specify the start channel number.

endChNo

Specify the end channel number.

spanMin

Specify the left value of the span.

spanMax

Specify the right value of the span.

scaleMin

Specify the left value of the scale.

scaleMax

Specify the right value of the scale.

scalePoint

Specify the decimal point position for scaling.

Description

Sets the specified DC current range to the measurement channels in the specified
channel range (specified by channel type, start channel number, and end channel

number).
This function executes the SR command of the DARWIN communication function.

It creates and sends the command and receives the response.
If the left and right values are the same, the span or scale designation is considered

omitted.

Return value

Returns an error number.

Reference

runCommand CDAQDARWINChInfo::toChRange

7.4 Details of the DARWIN Class

Advertising