Retrieval of the measured data – Yokogawa PC-Based MX100 User Manual

Page 1067

Advertising
background image

21-11

IM MX190-01E

21

DARWIN for Extended API - Visual Basic -

Retrieval of the Measured Data

Program Example

Attribute VB_Name = "Module1"
Public Sub Main()
'connect
comm = openDA100Reader("192.168.1.11", rc)
'get
rc = measInstChDA100Reader(comm, 0, 1)
Value = dataValueDA100Reader(comm, 0, 1)
'disconnect
rc = closeDA100Reader(comm)
End Sub

Description

Overview

Retrieves instantaneous values of the measured data from channel 1 of DARWIN
subunit number 0 and stores them in the field. Reads the measured values and

concludes the process.

Communication Connection
comm = openDA100Reader("192.168.1.11", rc)
The IP address of the DARWIN is specified. This statement specifies the
communication constant for the port number for loading the instantaneous value

data.

Retrieval of the Measured Data of Channel 1
rc = measInstChDA100Reader(comm, 0, 1)
Retrieves instantaneous values of the measured data from channel 1 of DARWIN

subunit number 0 and stores them in the field.

Reading Measured Values
Value = dataValueDA100Reader(comm, 0, 1)
Reads the measured value of channel 1 of subunit number 0 from the field where
the measured data is stored.

Comm. cut
rc = closeDA100Reader(comm)
Drops the connection.

21.4 Program for Loading Instantaneous Value Data - DARWIN/Visual Basic -