Setpowerdarwin – Yokogawa PC-Based MX100 User Manual

Page 530

Advertising
background image

10-32

IM MX190-01E

setPOWERDARWIN

Syntax

int setPOWERDARWIN(DAQDARWIN daqdarwin, int iRangePOWER, int
chType, int chNo, int iItem, int iWire, int spanMin, int
spanMax, int scaleMin, int scaleMax, int scalePoint);

Declaration

Public Declare Function setPOWERDARWIN Lib "DAQDARWIN"(ByVal
daqdarwin As Long, ByVal iRangePOWER As Long, ByVal chType As
Long, ByVal chNo As Long, ByVal iItem As Long, ByVal iWire As
Long, ByVal spanMin As Long, ByVal spanMax As Long, ByVal
scaleMin As Long, ByVal scaleMax As Long, ByVal scalePoint As
Long) As Long

Parameters

daqdarwin

Specify the device descriptor.

iRangePOWER Specify the power monitor range.
chType

Specify the channel type.

startChNo

Specify the channel number.

iItem

Specify the power measurement parameter.

iWire

Specify the power connection method.

spanMin

Specify the left value of the span.

spanMax

Specify the right value of the span.

scaleMin

Specify the left value of the scale.

scaleMax

Specify the right value of the scale.

scalePoint

Specify the decimal point position for scaling.

Description

Sets the specified power range on the specified channel (specified under channel

type and channel number).
• With the span and scale specification, if the left and right values are the same,

they are considered omitted.

• This function executes the SR command of the DARWIN communication function.

Return value

Returns an error number.
Error:

Not descriptor

No device descriptor.

Reference

CDAQDARWIN::setPOWER

10.1 Details of Functions - DARWIN (Visual C/Visual Basic) -