Yokogawa PC-Based MX100 User Manual

Page 973

Advertising
background image

17-239

IM MX190-01E

Functions for the MX100 (Extended API) - Visual C/Visual Basic/Visual Basic.NET/C# -

17

userTransmitMX100

Syntax

int userTransmitMX100(DAQMX100 daqmx100, int idTrans, int
aopwmNo);

Declaration

Visual Basic
Public Declare Function userTransmitMX100 Lib "DAQMX100"(ByVal
daqmx100 As Long, ByVal idTrans As Long, ByVal aopwmNo As
Long) As Long
Visual Basic.NET
Public Declare Ansi Function userTransmitMX100 Lib
"DAQMX100"(ByVal daqmx100 As Integer, ByVal idTrans As
Integer, ByVal aopwmNo As Integer) As Integer
C#
[DllImport("DAQMX100.dll" CharSet=CharSet.Auto,
EntryPoint="userTransmitMX100")]
public static extern int userTransmitMX100(int daqmx100, int
idTrans, int aopwmNo);

Parameters

daqmx100

Specify the device descriptor.

idTrans

Specify the transmission output data identifier.

aopwmNo

Specify the AO/PWM data number.

Description

Gets the transmission status of the specified AO/PWM data number from the output

transmission output data of the specified transmission output data identifier.
• If it does not exist, “Unspecified (Unknown)” is returned.

Return value

Returns the transmission status.

Reference

CDAQMX100::getClassMXTransmitList
CDAQMXTransmit::getTransmit
CDAQMXTransmitList::getClassMXTransmit

17.2 Details of Function - MX00 (Visual C/Visual Basic/Visual Basic.NET/C#) - Retrieval Functions