Lincoln Electric IM8001 PRODUCTION MONITORING 2.2 User Manual

Page 107

Advertising
background image

Chapter 5. Using Production Monitoring™

Weld Detail Tab

5.34

Production Monitoring™ User Manual

IM8001

Attribute

Description

Current Maximum Limit This column simply displays the high end of the arc current limit that was set in

the Weld Profile used to make the weld.

Current Percent Low

This value is the percentage of measurements taken during the weld (minus the
Start and End delays) that were below the low end of the arc current limit set in
the Weld Profile that was used to make this weld.

Current Percent High

This value is the percentage of measurements taken during the weld (minus the
Start and End delays) that were above the high end of the arc current limit set in
the Weld Profile that was used to make this weld.

Voltage Status

Weld Engineers can set each Weld Profile with a minimum and a maximum
voltage value that is considered acceptable. The Voltage Status field displays
whether this weld was within those limits or out of limits.

Voltage Minimum

The Voltage Minimum field displays the lowest arc voltage measurement taken
by the Welding Power Source throughout the duration of this weld (minus the
Start and End delays).

Voltage Average

Hundreds of times per second, the Welding Power Source takes a measurement
of the arc voltage while the welder is active for this weld (minus the Start and
End delays). When the weld is complete, the power source averages those
measurements together. The Voltage Average column displays that average arc
voltage value for this weld.

Voltage Maximum

The Voltage Maximum field displays the highest arc voltage measurement taken
by the Welding Power Source throughout the duration of this weld (minus the
Start and End delays).

Voltage Minimum Limit This column simply displays the low end of the arc voltage limit that was set in

the Weld Profile used to make the weld.

Voltage Maximum Limit This column simply displays the high end of the arc voltage limit that was set in

the Weld Profile used to make the weld.

Voltage Percent Low

This value is the percentage of measurements taken during the weld (minus the
Start and End delays) that were below the low end of the arc voltage limit set in
the Weld Profile that was used to make this weld.

Voltage Percent High

This value is the percentage of measurements taken during the weld (minus the
Start and End delays) that were above the high end of the arc voltage limit set in
the Weld Profile that was used to make this weld.

Wire Feed Speed Status Weld Engineers can set each Weld Profile with a minimum and a maximum wire

feed speed that is considered acceptable. The Wire Feed Speed Status field
displays whether this weld was within those limits or out of limits.

Wire Feed Speed
Minimum

The Wire Feed Speed Minimum field displays the lowest wire feed speed
measurement taken by the Welding Power Source throughout the duration of
this weld (minus the Start and End delays).