Appendix A. Additional Information

Archive of Data from the Database

A.4

Production Monitoring™ User Manual

IM8001

Table 5.1

Columns in the Weld Archive File

Column Heading

Description

ID

This is the database record number for the weld. When a Welding Power
Source sends weld records to the Production Monitoring™ database, the
database assigns an identification number to each weld. This column
represents that number, also known as the Weld ID in the main application.

WelderName

This column displays the name of the Welding Power Source used to make
this weld. This is the name of the power source at the time the weld was
made. It was entered by the Production Monitoring™ administrator when
adding the power source to the Asset Tree.

Model

This is the model of the Welding Power Source that made this weld. The
model information comes from the TOK file uploaded when adding the
Welding Power Source to the Asset Tree.

ProfileNumber

This column displays the number of the Weld Profile used at the time of the
weld. If a Weld Operator did not choose a Weld Profile for the weld, the
Welding Power Source automatically selected the last profile. For those
power sources utilizing 32 profiles, this is Profile 32. For those utilizing 200
profiles, the weld is assigned to Profile 200.

MachineCounter

When a Welding Power Source creates a weld, it assigns an identification
number to that weld for debugging purposes. The MachineCounter column
represents that number.

SerialNumber

The SerialNumber is the number that was assigned to this weld.

StartDateTime

The StartDateTime column displays the date and specific time the Welding
Power Source began performing the weld.

Duration

The Duration column displays the time it took to make the weld. This is the
length of time (in seconds) from the time listed in the StartDateTime column
to the time the Welding Power Source stopped welding.

EndDateTime

The EndDateTime column is a calculated value. The system added the
Duration column to the StartDateTime column to calculate the date and time
the Welding Power Source stopped welding.

Status

If any limit errors occurred during the weld, the Status column displays the
code of the error. If no error occurred during the weld, the value in this
column is 0. The following codes could appear in the Status column:

ƒ 0x8000 Fault

Latch

ƒ 0x4000 Fault
ƒ 0x2000 Alarm

Latch

ƒ 0x1000 Alarm
ƒ 0x0800 Unused

Bit

ƒ 0x0400 Unused

Bit