Chapter 5. Using Production Monitoring™

Downtime Tab

5.40

Production Monitoring™ User Manual

IM8001

Field

Description

Shift

If you want to see fault data for a specific shift during the date range you chose, select
that shift from the Shift drop-down. Production Monitoring™ narrows the data to
include only those faults that occurred during that shift. The Production Monitoring™
administrator configured the shifts on the Administration page of the application.

Top Quantity

The Top Quantity field is only available for the Chart report. Enter the maximum
number of different faults you want to include in the report.

For example, if you wanted to see a maximum of five (5) kinds of faults on the report,
you would enter 5 in the Top Quantity field.

Grid Report

The Grid report provides you with a list of faults that occurred for the single Welding Power Source or
Group of power sources you have selected in the Asset Tree. Table 5.23 explains the columns of the report
in more detail.

Figure 5.32 Downtime Grid Report

Table 5.23

Columns on the Downtime Grid Report

Field

Description

Fault

The Fault column displays the description of the fault that occurred on the Welding
Power Source
or Group of power sources you have selected in the Asset Tree.

If you want to see additional information about that individual fault, simply click the
underlined description. The system automatically generates a Fault Detail report for you
(page 5.41).

Duration

Each occurrence of the fault lasts for a period of time, whether a few seconds or a few
hours. The Duration column is the total accumulated time for each type of fault, adding
together the duration of every occurrence of that fault in the date range and shift
selected in the report’s criteria on the Welding Power Source or Group of power sources
you have selected in the Asset Tree.

Count

The Count column displays the number of times this fault occurred during the date range
and shift selected in the report’s criteria on the Welding Power Source or Group of
power sources you have selected in the Asset Tree.