Chapter 5. Using Production Monitoring™

Production Tab

5.20

Production Monitoring™ User Manual

IM8001

Table 5.10

Columns on the True Energy™ Report

Column

Description

Period

The Period column reflects the choice made in the Group Welds drop-down on the
Criteria window, as well as the Start Date/End Date range and Shift selected.

To generate a new, more detailed report for a specific Period in the report, click
the link. The system automatically generates the True Energy™ report on the
Welding Listing tab for you (page 5.28).

True Energy™ (kJ)

This column displays the average True Energy™ put into the welds made during
the time period displayed in the Period column by the Welding Power Source or
Group of power sources you have selected in the Asset Tree.

Total Arc Time

The Total Arc Time is the total number of hours that the Welding Power Source or
Group of power sources you selected in the Asset Tree were spent in the Welding
state during the time period listed in the Period column.

Duration/Count Report

The Duration/Count report is a great resource for reviewing how long your Welding Power Sources are
actually welding and how many welds they perform over specific time periods. You can generate this
report based on a single Welding Power Source or a Group of power sources, depending on what you have
selected in the Asset Tree.

Figure 5.19 Production Report: Duration/Count

The top half of the report is a graph that displays the total amount of time the power source spent in the
Welding state during the time period represented by the Period column below the graph. The report also