Lincoln Electric IM8001 PRODUCTION MONITORING 2.2 User Manual

Page 20

Advertising
background image

Requirements and Limitations

Chapter 1. General Information

IM8001

Production Monitoring™ User Manual

1.7

ƒ FANUC® ServoTorch Wire Feed Speed (WFS) will not be recorded for older software versions of

ArcTool® software and older versions of the Welding Power Source’s firmware. Starting with the
V7.70P/07 release of the ArcTool® software, ServoTorch WFS feedback is supported.

ƒ The robotic analog interface is not recommended when you use the Last Digit of Workpoint

method for selecting Weld Profiles. (Please refer to the Power Wave® Manager User Manual for
more details on this method.)

ƒ Production Monitoring™ does not support consumable package tracking or the calculation of

Wire Deposition with Dual-Head Wire Feeders.

ƒ When using the Windows XP Pro operating system for the server computer, only five (5) users at

a time can view reports.

ƒ When you have multiple machines with memory panels connected to your system (e.g., two

wire feeders that each have a memory panel of their own), the Weld Operator should not use
these buttons to choose the Weld Profile for their weld. You could potentially select the wrong
profile for the weld.

Table 1.1

Limitation Differences between Version 2.1 and Version 2.2

Item

Version 2.1

Version 2.2

Maximum weld duration (seconds)

6,553

429,496,729

Maximum weld records in Welding Power
Source memory

5,000

1,000

Shortest weld duration that can be
recorded (seconds)

0.5 0.2

Minimum total delay (i.e., Start Delay plus
End Delay) (seconds)

0.7

0.2

Maximum serial number length

16

32

Maximum out-of-limit tolerance time
(seconds)

1310.7

85,899,345

TIG and stick welding supported

No

Yes

WeldScore™ supported

No On third-generation Welding

Power Sources

Advertising