Chapter 5. Using Production Monitoring™

Production Tab

5.12

Production Monitoring™ User Manual

IM8001

Grid Report

The Grid report provides you with a list that summarizes the weld data from the production floor based on
the criteria you have selected for the report (Figure 5.13). You can see a Grid report for either a single
Welding Power Source or a Group of power sources. Table 5.5 explains the columns of the report in more
detail.

TIP |

Use

the

Criteria link to customize the data to meet your

needs. See Table 5.4 on page 5.11 for details on the criteria
available.

Figure 5.13 Production Report: Grid

Table 5.5

Columns on the Production Grid Report

Column

Description

Period

The Period column reflects the choice made in the Group Welds drop-down on
the Criteria window, as well as the Start Date/End Date range and Shift selected.
To generate a report for a specific Period in the report, click the link. The system
automatically generates a Grid report on the Weld Listing tab based on just the
period you clicked.

Welds

The Welds column reflects the total number of welds performed during the time
period represented by the Period column.

Welds Out of Limit

This column lists the number of welds listed in the Welds column that were out
of limit and what percentage of total welds that number represents.

Total Arc Time

The Total Arc Time is the total number of hours that the Welding Power Source
or Group of power sources you selected in the Asset Tree were spent in the
Welding state during the time period listed in the Period column.

WeldScore™

The WeldScore™ column represents the average score of the welds performed
during the time period displayed in the Period column for the Welding Power
Source
or Group of power sources you have selected in the Asset Tree. See
page 1.3 for more details on WeldScore™.

Advertising