Appendix A. Additional Information

Archive of Data from the Database

A.6

Production Monitoring™ User Manual

IM8001

Column Heading

Description

Voltage

VAvgValue

Hundreds of times per second, the Welding Power Source takes a
measurement of the arc voltage while the welder is active for this weld.
When the weld is complete, the power source averages those measurements
together. The VAvgValue column displays that average arc voltage value for
this weld.

VMinValue

The VMinValue column is the lowest arc voltage measurement taken by the
Welding Power Source throughout the duration of this weld.

VMaxValue

The VMaxValue column is the highest arc voltage measurement taken by the
Welding Power Source throughout the duration of this weld.

VLowPercent

This value is the percentage of measurements taken during the weld that
were below the arc voltage limit set in the Weld Profile used to make this
weld.

VHighPercent

This value is the percentage of measurements taken during the weld that
were above the arc voltage limit set in the Weld Profile that was used to
make this weld.

VLowLimit

This column simply displays the low end of the voltage limit that was set in
the Weld Profile used to make the weld.

VHighLimit

The value in this column is the high end of the voltage limit that was set in
the Weld Profile used to make the weld.

VIsLow

If the average voltage used to make the weld fell below the low end of the
limit set for the Weld Profile that was used, the value in the VIsLow column
will be 1. Otherwise, the value will be 0.

VIsHigh

If the average voltage used to make the weld was above the high end of the
limit set for the Weld Profile that was used, the value in the VIsHigh column
will be 1. Otherwise, the value will be 0.

VBaseUnits

The VBaseUnits column simply displays the voltage units used in this weld
record. Typically, this is set to V for “volts”.

Current

CAvgValue

Hundreds of times per second, the Welding Power Source takes a
measurement of the arc current while the welder is active for this weld.
When the weld is complete, the power source averages those measurements
together. The CAvgValue column displays that average arc current value for
this weld.

CMinValue

The CMinValue column is the lowest arc current measurement taken by the
Welding Power Source throughout the duration of this weld.