5.2. EFF – SETTINGS FOR TESTING PV SYSTEMS (ONLY SOLAR I-V)
Further in this manual, the acronym MPPT (Multiple Power Point Tracker) shall indicate
the characteristic of the DC/AC converter (inverter), capable of maximizing the DC power
which can be taken from the photovoltaic field. See § 11.2 for further details.

5.2.1. Settings for PV systems with single-MPPT inverter - single-phase AC output
Check beforehand the settings made in MENU

SETRemote Unit and check that you

have selected “SOLAR” as setting for parameter “R. unit”.

5.2.1.1. Instrument

settings

1. Press MENU key, move the cursor to “EFF” by means of

the arrow keys (

,) and confirm with ENTER. The

screen with the values of electrical parameters relative to
PV generator is displayed

15/05/10 15:34:26

P r p

- - -

I r r

- - -

W / m 2

P n o m

0 . 0 0 0

k W

T c

- - -

° C

T e

- - -

° C

P d c

0 . 0

k W

V d c

0 . 0 0 0

V

I d c

0 . 0

A

n d c

- - -

G O – S t a r t r e c

Select

E F F


2. Press ENTER key. The options Set PV plant and Set

Instrum. are displayed

3. By means of the arrow keys (

,) to select Set Instrum.

and confirm with ENTER. The herewith screen is shown:

15/05/10 15:34:26

P R p

- - -

I r r

- - -

W / m 2

P n o m

0 . 0 0 0

k W

T c

- - -

° C

T e

- - -

° C

P d c

0 . 0

k W

V d c

0 . 0 0 0

V

I d c

0 . 0

A

n d c

- - -

Set PV plant

S e t I n s t r u m .

Select

E F F


4. By means of the arrow keys (

,) the herewith

parameters are set:
 IP (integration period) used by meter during yield test

recording. The values I 5s, 10s, 30s, 60s, 120s, 300s,
600s, 900s, 1800s, 3600s
are selectable

 The full scale (FS) of DC clamp used on DC current

measurement with selectable value within 1A

3000A

 The full scale (FS) of AC clamp used on AC current

measurement with selectable value within 1A

3000A

5. Press the SAVE key to save the settings made; the

message “Data saved” will be displayed for a few
seconds. Press the ESC/MENU key to exit without saving
and go back to the previous screen.

15/05/10 15:34:26

I P

:  5  s

F S D C c l a m p

: 1 0 0 0 A

F S A C c l a m p

: 1 0 0 0 A

SAVE to store data

E F F


Advertising