I-V400 - SOLAR I-V

EN - 44

22. The instrument displays a screen similar to the one

reported here to the side, where:
 Vdc = DC output voltage from module/string
 Irr = irradiance measured by supplied reference cell
 Tc = temperature of module. The herewith options are

available for this field:

 AUTO  automatic mode of temperature measurement
 Number  MAN or AUX mode of temp. measurement
 “ - - - “  AUX mode with no connected probe
 Module = type of selected module
 Temp = measurement mode of module temperature
 The symbol “

fixed at display means that a stable

RF connection is established with the remote unit
SOLAR-02

15/05/10 15:34:26

V d c = 3 6 7 V

I r r = 1 0 4 5 W / m 2

T c = 4 5 ° C

Module: SUNPOWER 210

Select

I – V

23. Press ENTER key, select the “Activate Rec.” item and

confirm with ENTER. The message “Remote unit in
recording…” is displayed on the meter. In this condition is
possible to start the I-V curve tests always considering
that the complete results will be available only after the
stop of recording of SOLAR-02 and transfer them from the
same remote unit

15/05/10 15:34:26

V d c = 0 . 0 V

I r r = - - - W / m 2

T c = - - - ° C

A c t i v a t e R e c .

S e t t i n g s

M e a s . T y p e 

Select

I – V

CAUTION

At the press of GO/STOP key some different error messages can be
displayed by the meter (see § 6.4) and, due of this, the test cannot start.
Check and remove, if possible, this error message before start the test


24. Press GO/STOP key to start the test. If none of the

previous error messages are detected, the message
Measuring…” is shown on the display for some seconds,
depending on the level of power during test.

15/05/10 15:34:26

V d c = 3 6 7 V

I r r = - - - W / m 2

Tc = Auto °C


Module: SUNPOWER 210

Measuring…

Select

I - V