I-v400 - solar i-v – HT instruments SOLAR I-V User Manual

Page 47

Advertising
background image

I-V400 - SOLAR I-V

EN - 45

25. At the end of test, based on the descriptions of previous

points, the message “STC Data available after Stop rec” is
displayed and then the results at OPC conditions are
displayed

15/05/10 15:34:26

V o c

= 1 5 . 2

V

V m p p = 1 4 . 7

V

I m p p

= 4 . 7

A

I s c

= 5 . 2

A

P m a x = 2 0 0

W

F F

= 7 7 . 1

%

I r r

=

- - -

W / m

2

T c

= A u t o

Results @ OPC

Select

I - V

26. Press ENTER for the visualization of measurement results

both in numeric and graphical mode (§ 6.2.3)

27. Use the arrow key

 for the selection of table or graph

visualization

28. Press SAVE key to store the result of test or ESC/MENU

key to exit without saving and to go back to the main
screen

15/05/10 15:34:26

V o c =

1 5 . 2

V

V m p p = 1 4 . 7

V

I m p p = 4 . 7

A

I s c =

5 . 2

A

P m a x = 2 0 0

W

F F =

7 7 . 1

%

I r r

=

- - -

W / m

2

T a b l e 

G r a p h 

Select

I - V


29. At the end of I-V test, press the ENTER key, select the

Stop recording” item and confirm with ENTER. The
messages “Wait…” and then “STC Data available in MEM”
are displayed

30. In this conditions, for the I-V tests performed with

irradiance values over the limit threshold and stable, the
correspondent STC results will be available inside memory

15/05/10 15:34:26

V d c = 0 . 0 V

I r r = - - - W / m 2

T c = A u t o ° C

S t o p R e g .

S e t t i n g s

M e a s . T y p e 

Select

I - V


31. The message “Download data” is displayed on the instrument and, at the same time,

the message “Send” is displayed on SOLAR-02 which means the transfer of irradiance
values and, if necessary, the module temperature values on the main unit

32. At the end of data transfer the instrument automatically join the average value of

irradiance (detected with IP = 5s) to each I-V test performed and, correspondingly, will
calculate the results translated to STC conditions and the Yes/No response for each
test. The complete results are recalled at display as described in § 7.3.2. See the §
6.2.3 for the meaning of measurement results



Advertising
This manual is related to the following products: