Technical specifications – HT instruments SOLAR I-V User Manual

Page 69

Advertising
background image

I-V400 - SOLAR I-V

EN - 67

10. TECHNICAL SPECIFICATIONS

10.1. YIELD TEST TECHNICAL FERATURES (ONLY SOLAR I-V)
Accuracy is calculated as [%reading+(number of dgt) * resolution] at 23°C ± 5°C, <80%HR

VDC Voltage

Range [V]

Resolution [V]

Accuracy

15.0

 999.9

0.1

(0.5rdg + 2dgt)

AC TRMS Voltage

Range [V]

Resolution [V]

Accuracy

50.0

 265.0

0.1

(0.5rdg + 2dgt)

Max crest factor: 1.5

DC Current (by external transducer clamp)

Range [mV]

Resolution [mV]

Accuracy

-1100

 -5

0.1

(0.5rdg + 0.6mV)

5

 1100

The value of current is ALWAYS displayed with positive sign ; The value of current transduced in voltage less then 5mV is zeroed

AC TRMS Current (by external transducer clamp)

Range [mV]

Resolution [mV]

Accuracy

1

 1200

0.1

47.5

 63.0

Max crest factor: 2.0 ; The value of current transduced in voltage less then 5mV is zeroed

FS DC and AC clamp [A]

Resolution [A]

Minimum read value [A]

DC AC

1< FS

 10

0.001 0.05

0.01

10< FS

 100

0.01 0.5

0.1

100< FS

 1000

0.1 5A

1

DC Power (Vmis > 150V)

FS clamp [A]

Range [W]

Resolution [W]

Accuracy

1< FS

 10

0.000k

 9.999k

10.00k

 99.99k

0.001k

0.01k

(0.7rdg + 3dgt)

(Imis < 10%FS)

10< FS

 100

0.000k

 9.999k

10.00k

 99.99k

0.001k

0.01k

(0.7rdg)

(Imis

 10%FS)

100< FS

 1000

0.00k

 99.99k

100.0k

 999.9k

0.01k

0.1k

Vmis = voltage at which power is measured ; Imis = measured current

AC Power (Vmis > 200V, PF=1)

FS clamp [A]

Range [W]

Resolution [W]

Accuracy

1< FS

 10

0.000k

 9.999k

10.00k

 99.99k

0.001k

0.01k

(0.7rdg + 3dgt)

(Imis < 10%FS)

10< FS

 100

0.000k

 9.999k

10.00k

 99.99k

0.001k

0.01k

(0.7rdg)

(Imis

 10%FS)

100< FS

 1000

0.00k

 99.99k

100.0k

 999.9k

0.01k

0.1k

Vmis = voltage at which power is measured ; Imis = measured current

Frequency

Range [Hz]

Resolution [Hz]

Accuracy

47.5

 63.0

0.1

(0.2rdg + 1dgt)

Irradiance (with reference reference cell)

Range [mV]

Resolution [mV]

Accuracy

1.0

 100.0

0.1

(1.0rdg + 5dgt)

Temperature (with auxiliary probe)

Range [°C]

Resolution [°C]

Accuracy

-20.0

 100.0

0.1

(1.0rdg + 1°C)