I-V400 - SOLAR I-V
EN - 52
6.3.3. Fast check IVCK without irradiance measurement
CAUTION
The maximum voltage among inputs P1, P2, C1 and C2 is 1000V DC. Do not
measure voltages exceeding the limits expressed in this manual.
The maximum current allowable for the instrument is 10A. Do not effect tests
in parallel on FV module strings.
Never effect tests on modules or FV strings connected to DC/AC converter.
1. Turn on the instrument pressing ON/OFF
2. Check that remote unit SOLAR-02 is not selected (see § 5.1.4– setting NO)
3. Check that the value of minimum irradiance set in the section “Irradiance” (see §5.1.5)
is equal to 0
4. Go back to main MENU and select “I-V”
5. Select “I-V” and press ENTER to enter the section of FV module performance
measurement. Generally when selecting I-V on general menu the instrument automatically
shows the last mode under use (I-V or IVCK).
6. In case the current mode is not IVCK, press ENTER,
select “Measurement ” by means of arrow keys
(
,). Use the arrow key to enter the internal
submenu, select “IV Check” and confirm pressing
ENTER to start up the initial screen of fast check IVCK.
15/05/10 15:34:26
V d c = 0 . 0 V
I r r = 0 W / m 2
T c = - - - ° C
Module: SUNPOWER 210
F e a t u r e
I V
I m p
M e a s u r e m e n
t R S
M i s
I V C h e c k
Selection
I - V
7. Check the preliminary settings based on descriptions of § 6.3.2
8. Connect the instrument to the module/string under test as shown in the following
picture. In particular connect the negative pole of the module/string to terminals P1, C1
and it positive pole to terminals P2, C2.
CAPTION:
P1: Black cable
P2: Blue cable
C1: Green cable
C2: Red cable
1:
Module or FV string
Fig. 10: Connection to module/FV string for IVCK tests without irradiance measurement