I-V400 - SOLAR I-V

EN - 57

6.4. LIST OF DISPLAY MESSAGES

MESSAGE DESCRIPTION

Voltage too low

Check the voltage between C1 and C2 input terminals

Vin > 1000

DC output voltage from module/string > 1000V

Irradiance too low

Irradiance value lower than threshold limit

NTC Error

Internal NTC damaged. Contact service dpt

Please wait for cooling…

Instrument overheated. Wait before starting the tests again

Memory full

Internal memory full. Download data to PC

Pulse width too long

Anomalous condition. Repeat test with more modules

Current too low

Measured current lower than the minimum detectable

Vdc wrong connection

Check the voltage between C1 and C2 input terminals

Negative voltage

Check the polarity of input terminals

Data base full

The number of modules defined is > 30

Data @ STC unavailable

The meter does not calculate the date at STC conditions

Irradiance too high

Irradiance value higher than the maximum range

Data unavailable

Generic error. Repeat the test

Isc too high

Output current higher than maximum range

Wrong date

Set a correct date/hour on meter

Error 1/2/3/4/5: contact Assistance

Contact service dpt

Error EEPROM : contact Assistance

Contact service dpt

Error FLASH : contact Assistance

Contact service dpt

Error RTC : contact Assistance

Contact service dpt

Battery low

Low battery indication. Fit new batteries inside meter

Error: Vmpp >= Voc

Check the settings of module inside DB

Error: Impp >= Isc

Check the settings of module inside DB

Error: Vmpp * Impp >= Pmax

Check the settings of module inside DB

Error: alpha too high

Check the settings of module inside DB

Error: beta too high

Check the settings of module inside DB

Error: Toll too high

Check the settings of module inside DB

Error: gamma too high

Check the settings of module inside DB

Module already present

Name of module just used inside DB

Delta-Irrad. too high. Retry

Unstable condition on irradiance. Repeat the test

Voltage not steady

Anomalous condition. Repeat test with more modules

Unsteady Current

Difference between 2 consec. Instant. values of current is > 0.13A

Firmware mismatch

Problem with internal FW. Contact service dpt

Ref. Cell temp over range

Temperature measured by reference cell is too high

PV module temp over range

Temperature of module over maximum range

Wrong Mod. Num. Continue?

Setting of number of modules not ok with measured Voc

Ref. Cell temp not detected (ENTER/ESC)

Measure on the cell of module not performed

Unable to calculate Rs value

Rs value external to measurement range

Thermal Instability

The instrument detect unsteady conditions (see § 10.2)

Error during memory writing

Problem with the access to internal memory

Error Radio: contact Assistance

Contact service dpt

Error Radio transmission

Contact service dpt

Error during download

Contact service dpt

Recording downloaded

Recording corrected downloaded on the instrument

Radio connection activated

Corrected RF connection with remote unit SOLAR-02

Wait data analysis

Download data from SOLAR-02 and wait for response

Unable execute analysis

Problem on downloaded data from SOLAR-02. Verify settings

I < Lim

Output current lower that the minimum measurable

CAUTION: internal short

Contact service dpt

Remote unit not detected Enter/Esc

Unit SOLAR-02 do not RF connected to the instrument

Rem. Unit in rec

Unit SOLAR-02 in recording parameters Irr/Temp

STC Data available after Stop rec.

Stop the recording to obtain STC data

STC Data available in MEM

Data STC condition save on memory

Verify connect. P1

Check the proper insertion of test cable in the input P1

Error in data download from SOLAR-02

SOLAR I-V set for use with MPP300. Error in download from SOLAR-02.

SOLAR-02 not detected. Stop Rec.?

SOLAR I-V set for use with MPP300. SOLAR-02 not detected when stopping Rec

MPP300 not detected

SOLAR I-V set for use together with MPP300. MPP300 not detected

SOLAR-02 not detected.

SOLAR I-V set for use together with MPP300. SOLAR-02 not detected.

MPP300: negative AC power

MPP300 has detected negative AC powers.

MPP300: inverted AC and DC voltages

MPP300 has detected inverted AC and DC voltages

No power supply to MPP. Continue? Enter/Esc

MPP300 has not detected the presence of the external power supply.