Storing data, I-v400 - solar i-v, En - 58 – HT instruments SOLAR I-V User Manual

Page 60

Advertising
background image

I-V400 - SOLAR I-V

EN - 58

7. STORING DATA

The meter allows storing 99 results of PV checks (only SOLAR I-V) and 249 tests of I-V
curve in its internal memory. In the PV check operation it’s also possible to save the
instantaneous values at display. The saved data can be recalled at display and deleted in
each moment, and can be associated (for I-V curve test) to reference numerical markers
relevant to the installation name, the PV string and the PV module (max 255 markers).

7.1. SAVING TEST RESULTS OF PV CHECKS (ONLY SOLAR I-V)

1. Press SAVE key with a measured result shown at display

or for saving the instantaneous values. The right screen
with a virtual keyboard is displayed by the meter

2. Use the arrow keys (

,) and ( , ) to fit a short

description (max 12 chars) relative to the PV check

3. Press SAVE key to store the result of test or ESC/MENU

key to exit without saving

15/05/10 15:34:26

P R p

0 . 8 5 1

I r r

8 2 7

W / m 2

P n o m

3 . 5 0 0

k W

T c

4 5

° C

T e

3 0

° C

K E Y B O A R D

A B C D E F G H I

A B C D E F G H

I

J K L M N O P

Q R S T U V W X Y Z - + 0 1 2 3
4 5 6 7 8 9 S P A C E

D E L

SAVE for store data


7.2. SAVING TEST RESULTS OF I-V CURVE TEST

1. Press SAVE key with a measured result shown at display.

The following screen is displayed where the herewith items
are shown:
 The first memory location available (“Measurement”)
 The numerical marker “Installation”
 The numerical marker “String”
 The numerical marker “Module”
 The field “Comment” where the operator can include a

short description (max 14 char) by using virtual keyboard

15/05/10 15:34:26

M e a s u r e m e n t : 0 0 7

I n s t a l l a t i o n :

0 1 0

S t r i n g : 0 0 9

M o d u l e : 0 0 4

C o m m e n t :

K E Y B O A R D

A B C D E F G H I

A B C D E F G H

I

J K L M N O P

Q R S T U V W X Y Z - + 0 1 2 3
4 5 6 7 8 9 S P A C E

D E L

SAVE for store data

C o m m e n t

MEM – IV


2. Use the arrow keys (

,) to select the items and (,) to set the numeric value of the

markers and to use the virtual keyboard. “Comments” field modifications are possible
only by changing the number of the “Installation” marker inserting one among the
available markers

3. Press ENTER to digit any character of the desired name
4. Press SAVE key to store the result of test or ESC/MENU key to exit without saving.













Advertising