Caution – HT instruments SOLAR I-V User Manual

Page 43

Advertising
background image

I-V400 - SOLAR I-V

EN - 41

6.2.2.2. I-V curve test by remote unit SOLAR-02 in synchro recording
This mode, which consists in an independent recording of the irradiance and temperature
parameters by the remote unit SOLAR-02, permits to perform I-V curve test also with wide
distance between the instrument and SOLAR-02 without any connection between them.
On the other hand, due to the impossibility for the meter to have immediately the values of
irradiance/temperature, it is necessary wait the transfer of data from remote unit SOLAR-
02 to main unit in order to have all the available results.

CAUTION

 The maximum voltage among P1, P2, C1, and C2 inputs is 1000V DC. Do

not measure voltages exceeding the limits prescribed by this manual

 The maximum current measured by the meter is 10A. Do not perform test

on strings of PV modules in parallel with them

 Do not perform test on PV modules or strings connected to DC/AC

converter


1. Turn on the meter by pressing ON/OFF key
2. Check that option YES relative to the selection of remote unit SOLAR-02 should be set

on the instrument (see § 5.1.4)

3. Check that the value set on “Irradiance” section (see § 5.1.5) should be consistent with

the measurement to perform. It is suggested to perform the measurement with a
threshold

 700 W/m

2

in compliance to the IEC/EN60891 guideline

4. Back to the main menu and select the “I-V” measurement mode
5. Press ENTER, by means of arrow keys (

,) select

item “Meas. Type ”

6. Using the

 key, select item “I-V Test” and confirm by

pressing ENTER

15/05/10 15:34:26

V d c = 0 . 0 V

I r r = 0 W / m 2

T c = - - - ° C

Module: SUNPOWER 210

I - V T e s t

S e t R S

T e s t

M e a

I V F a s t C h e c k

Select

I - V

7. Switch on the remote unit SOLAR-02 and wait that “Radio connection active” message

is displayed

8. Check the status of internal batteries of SOLAR-02 (the “

” symbol should be not

displayed)

9. Check that the values of sensitivity and temperature coefficient set on the SOLAR-02

section should be consistent with the reference cell depending on the kind of
module/string on test (see user manual of SOLAR-02)