13. The display shows the first screen containing the values

of the electrical parameters on the DC side of the inverter.

15/05/10 15:34:26

P R p

- - -

I r r

- - -

W / m 2

P n o m 3 . 5 0 0

k W

T c

4 5

° C

T e

3 0

° C

P d c

3 . 1 2 5

k W

V d c

3 8 9

V

I d c

8 . 0 1

A

n d c

- - -

G O – s t a r t r e c .

Select

E F F


14. By means of arrow key

 to access to the second screen

with the values of electrical parameters of the AC side of
inverter. Before to start the recording:

 Verify the symbol “

” blinking at display which

means the search by the meter of RF connection with
the remote unit SOLAR-02

 Verify that the Pac active power should be a positive

value. In the opposite case open the AC clamp and
rotate of 180 degree on the phase conductor

 Verify that the AC efficiency

ac = Pac / Pdc should be

a consistent value (e.g.: a situation of

ac > 1 is not

physically possible)

15/05/10 15:34:26

P d c

3 . 1 2 5

k W

V d c 3 8 9

V

I d c

8 . 0 1

A

n d c

- - -

° C

P a c

3 . 0 1 2

k W

V a c

2 3 1

V

I a c

1 3 . 0 3

A

n a c

0 . 9 6

G O – s t a r t r e c

Select

E F F


15.

With remote unit always close to the main unit press
GO/STOP key to start the recording. The “Rec. Start
waiting…
” message is shown at display of main unit and the
HOLD” message is shown at display of SOLAR-02 more
than the indication of residual time for “00” instance

15/05/10 15:34:26

P d c

3 . 1 2 5

k W

V d c 3 8 9

V

I d c

8 . 0 1

A

n d c

- - -

° C

P a c

3 . 0 1 2

k W

V a c

2 3 1

V

I a c

1 3 . 0 3

A

n a c

0 . 9 6

R e c . S t a r t w a i t i n g …

Select

E F F


16. When the “00” instant after the press of GO/STOP key is

reached, the recording starts and the units are correctly
synchronized. In these conditions the message “Rec
running…
” is displayed on the main unit and the
Recording…” message is displayed on the SOLAR-02

15/05/10 15:35:00

P d c

3 . 1 2 5

k W

V d c 3 8 9

V

I d c

8 . 0 1

A

n d c

- - -

° C

P a c

3 . 0 1 2

k W

V a c

2 3 1

V

I a c

1 3 . 0 3

A

n a c

0 . 9 6

R e c . R u n n i n g …

Select

E F F