6.2.2. I-V curve measurement by use of remote unit SOLAR-02
The I-V curve test with Irr/Temp measurement by use of remote unit SOLAR-02 can be
performed in one of the herewith mode:

 Remote unit SOLAR-02 in RF connection with main unit
 Remote unit SOLAR-02 in synchro recording (no RF connection with main unit)

6.2.2.1. I-V curve test by remote unit SOLAR-02 in RF connection
This mode is possible ONLY if the distance between the main unit and the remote unit
SOLAR-02 can establish always a stable RF connection. This distance limit is influenced
by obstacles, air humidity, etc., so it is considered valid about some meters.

CAUTION

 The maximum voltage among P1, P2, C1, and C2 inputs is 1000V DC. Do

not measure voltages exceeding the limits prescribed by this manual

 The maximum current measured by the meter is 10A. Do not perform test

on strings of PV modules in parallel with them

 Do not perform test on PV modules or strings connected to DC/AC

converter

1. Turn on the meter by pressing ON/OFF key
2. Check that option YES relative to the selection of remote unit SOLAR-02 should be set

on the instrument (see § 5.1.4)

3. Check that the values set on the “Remote unit” section (see § 5.1.4) should be

consistent with the reference cell depending on the kind of module/string on test

4. Check that the value set on “Irradiance” section (see § 5.1.5) should be consistent with

the measurement to perform. It is suggested to perform the measurement with a
threshold

 700 W/m

2

in compliance to the IEC/EN60891 guideline

5. Back to the main menu and select the “I-V” option
6. Press ENTER, by means of arrow keys (

,) select

item “Meas. Type ”

7. Using the

 key, select item “I-V Test” and confirm by

pressing ENTER

15/05/10 15:34:26

V d c = 0 . 0 V

I r r = 0 W / m 2

T c = - - - ° C

Modulo: SUNPOWER 210

I - V T e s t

S e t R S

T e s t

M e a

I V F a s t C h e c k

Select

I - V

8. Switch on the remote unit SOLAR-02 and wait that “Radio connection active”