KROHNE IFC 110 Converter User Manual

Page 72

Advertising
background image

Sect. 7.5

Part C Special applications, functional checks, service, and order numbers

72

IFC 110 F

05/2003

Group I

Faults / Symptoms

Cause

Remedial action

I 1

Receiver instrument

indicates ”0”

Invoke test function 2.03

for analysis see Sect.7.4.

Display shows...

(this check is only usefully,

I SHORT Eliminate

short

circuit,

if current output is operating in Current output shorted,

Load must be

≥ 15 Ω !

active mode, see Sect. 6.8!)

Load is < 15

I

OPEN

Find interruption and eliminate.

Load resistance > 500

No information displayed

after test

as described for faults I 2 and I 9

I 2

Receiver instrument

Wrong connection/polarity

Connect properly,

indicates “0“.

see Sect. 2.2 and 2.6.

act

iv

e mo

d

e

Circuit and/or receiver
instruments defective

Check circuit and receiver
instrument at I

S

/ I and replace

if necessary. Check position of
jumper X3 + X6 for active mode,
see Sect. 6.8 and check fuse F9
on I/O PCB and replace if
necessary, see Sect. 8.4
and 8.7.

Receiver instruments and/or
exernal voltage source
defective

Check connections, receiver
instruments and external voltage
source and replace if necessary.

p

assiv

e

mo

d

e

Internal power supply (E+E-)
is voltage source, shorted or
defective current output

Check connections and cables,
see Sect. 2.3 and 2.6.
Voltage between E+and E-
approx. 24 V. If voltage is a lot
smaller, switch off the instru-
ment, eliminate the short circuit,
check position of jumper
X3 + X6 for passive mode,
(see Sect. 6.8) and replace
fuses F1 and F8 on the I/O PCB
if necessary. Switch the
instrument back on. If it still
does not operate, current output
is defective. Replace I/O PCB or
complete electronic unit,
see Sect. 8.3 and/or 8.4.

Defective current output

Replace I/O PCB (see Sect. 8.4)
or consult KROHNE Service,
having first noted down hard-
ware information and error
status, see Sect. 7.3, Fct. 2.02.

Wrong flow direction setting

Set properly in Fct. 3.1.

Current output switched off

Switch on in Fct. 1.5.

Advertising