KYORITSU 1062 User Manual

Page 15

Advertising
background image

73

AC Current Measurement [RMS]

A

KEW1061

Rms-value detection, Crest factor: <3

Range

Resolution

Accuracy

Voltage Drop Maximum Input

Current

10 to 20Hz 20Hz to 1kHz

500μA

0.01μA

1.5+20

1+20

<0.11 mV/μA 440mA Protected

by a 440mA/

1000V fuse.

5000μA

0.1μA

50mA

0.001mA

<4mV/mA

500mA*3

0.01mA

5A

0.0001A

<0.1V/A 10A Protected by a

10A/1000V fuse.

10A

0.001A

AC Current Measurement [RMS]

A

KEW1062

Rms-value detection, Crest factor: <3

Range

Resolution

Accuracy

Voltage

Drop

Maximum Input

Current

10 to 20Hz 20Hz to 1kHz 1k to 5kHz

500μA

0.01μA

1+20

0.75 +20

1+30

<0.11

mV/μA 440mA Protected

by a 440mA/

1000V fuse.

5000μA

0.1μA

50mA

0.001mA

<4 mV/mA

500mA *3

0.01mA

5A

0.0001A

1.5+20

1+20

2+30

<0.1 V/A 10A Protected by

a 10A/1000V fuse.

10A

0.001A

Model KEW1061/1062
Accuracy At 5 to 100% of range, At 10 to 100% of range for 10A Range
*3: Maximum measurement current : 440mA at 500mA range
Response time: 1 sec max.

Advertising